SS150 Standing Seam Tray – Long Run Roofing
Freeman Roofing Standing Seam SS150 is a concealed-fix tray roofing and wall cladding system designed for architectural projects where clean lines and performance matter. It is manufactured custom cut to length (subject to transport and site limitations), with tray widths selectable to suit project requirements.
Key features
- Concealed clip fixing for a clean, uninterrupted finish
- 38 mm rib height for robustness and water-carrying capacity
- Variable tray widths, typically 300–510 mm, to suit design and performance requirements
- Suitable for roofing and wall cladding when correctly designed and detailed
Minimum roof pitch
Minimum roof pitch 3°, when the system is designed and detailed in accordance with Freeman Roofing SS150 design details and relevant New Zealand compliance pathways.
Where it’s used
- Architectural residential roofing
- Low-pitch roofing applications (project-specific design required)
- Wall cladding applications with a drainage cavity
Important design notes
- Thermal movement: detailing must allow for expansion and contraction; detailing should remain consistent across the roof system (do not mix detail “options”).
- Oil canning: tray roofing can show waviness depending on lighting, substrate stiffness, pan width, and viewing angle; this is a normal characteristic and not considered a defect.
- Low pitch (<10°): purlin spacing and underlay support may require adjustment.
- Wind zones and substrate: substrate requirements may vary depending on wind zone, exposure, tray width, and material selection, and should be confirmed as part of the project-specific design.
Talk to your local branch
For product availability, sheet length constraints, and coordination of project-specific requirements, contact your local Freeman Roofing team.
Compliance note
SS150 must be installed in accordance with Freeman Roofing design details, the NZ Metal Roofing Manufacturers (MRM) Code of Practice, and relevant New Zealand Building Code compliance pathways. Buildings outside the scope of standard acceptable solutions may require project-specific design and consenting.
Standing Seam Roof Drawings
Select Format
PDF Specifications
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing2.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Head-Flashing.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing2.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Jamb-Flashing.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Sill-Flashing.pdf
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Wall-Base-Flashing.pdf
- 2023-07-18_Freeman-Group-SST-Change-of-Pitch-SST-CP1.pdf
DWG Specifications
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing2.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Head-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing2.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Jamb-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Sill-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Wall-Base-Flashing.dwg
- 2023-07-18_Freeman Group -SST-Change-of-Pitch.dwg
DWG Specifications – 2004
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-External-Corner-Flashing2.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Head-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Internal-Corner-Flashing2.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Jamb-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Sill-Flashing.dwg
- 2019-11-13_Freeman-Group-Standard-Drawings-SST-Wall-Base-Flashing.dwg
PDF Specifications
- 2019-10-14_Freeman-Group–SST-Apex-Barge.pdf
- 2019-10-14_Freeman-Group–SST-Barge.pdf
- 2019-10-14_Freeman-Group–SST-Barge2.pdf
- 2019-10-14_Freeman-Group–SST-Cover.pdf
- 2019-10-14_Freeman-Group–SST-Full-Set.pdf
- 2019-10-14_Freeman-Group–SST-Gutter.pdf
- 2019-10-14_Freeman-Group–SST-Profile.pdf
- 2019-10-14_Freeman-Group–SST-Ridge-&-Hip.pdf
- 2019-10-14_Freeman-Group–SST-Side-Apron.pdf
- 2019-10-14_Freeman-Group–SST-Upper-Apron.pdf
- 2019-10-14_Freeman-Group–SST-Valley.pdf
DWG Specifications
- 2019-10-14_Freeman-Group–SST-Apex-Barge.dwg
- 2019-10-14_Freeman-Group–SST-Barge.dwg
- 2019-10-14_Freeman-Group–SST-Barge2.dwg
- 2019-10-14_Freeman-Group–SST-Cover.dwg
- 2019-10-14_Freeman-Group–SST-Gutter.dwg
- 2019-10-14_Freeman-Group–SST-Profile.dwg
- 2019-10-14_Freeman-Group–SST-Ridge-&-Hip.dwg
- 2019-10-14_Freeman-Group–SST-Side-Apron.dwg
- 2019-10-14_Freeman-Group–SST-Upper-Apron.dwg
- 2019-10-14_Freeman-Group–SST-Valley.dwg
DWG Specifications – 2004
- 2019-10-14_Freeman-Group–SST-Apex-Barge.dwg
- 2019-10-14_Freeman-Group–SST-Barge.dwg
- 2019-10-14_Freeman-Group–SST-Barge2.dwg
- 2019-10-14_Freeman-Group–SST-Cover.dwg
- 2019-10-14_Freeman-Group–SST-Gutter.dwg
- 2019-10-14_Freeman-Group–SST-Profile.dwg
- 2019-10-14_Freeman-Group–SST-Ridge-&-Hip.dwg
- 2019-10-14_Freeman-Group–SST-Side-Apron.dwg
- 2019-10-14_Freeman-Group–SST-Upper-Apron.dwg
- 2019-10-14_Freeman-Group–SST-Valley.dwg
OTHER ROOFING AND WALL CLADDING PROFILES
Corrugate
Corrugate roofing is a timeless classic and one of New Zealand’s most used roofing profiles.
Six Rib
Six Rib roofing has an extra rib compared to most other products, giving it a distinctive profile and greater rigidity.
Five Rib
Five Rib roofing is light, strong and stylish, perfect for both domestic and commercial applications.
Alpine Tray
The Alpine Tray profile provides greater water carrying capacity and strength for snow loading uses in alpine regions.